-50%
Philips HF-P 2 22-42 PL-T C L TL5C EII 220-240V 91399930 Online Hot Sale
Original price was: $22.95.$11.48Current price is: $11.48.
24 people are viewing this right now

Guaranteed safe & secure checkout
Description
Additional Information
Questions
Description
Specifications
- General Information
-
-
Remarks
UK importer address: Signify Commercial UK Limited, 3, Guildford Business Park, GU2 8XG
Application code
EII
Type version
mk4
Lamp type
PL-T C L TL5C
Number of lamps
2 piece unit
Number of products on MCB (16 A type B) (nom.)
12
Automatic restart
Yes
-
- Operating and Electrical
-
-
Input Voltage
220 to 240 V
Input frequency
50 to 60 Hz
Operating frequency (max.)
– kHz
Operating frequency (min.)
42 kHz
Operating frequency (nom.)
45 kHz
Ignition method
Warm Start
Crest factor (max.)
1.7
Power factor 100% load (nom.)
0.95
Ignition time (max.)
0.52 s
Mains voltage performance (AC)
-8%-+6%
Mains voltage safety (AC)
-10%-+10%
Earth leakage current (nom.)
0.5 mA
Inrush current width
0.35 ms
Constant wattage deviation
-2% +2%
Ballast factor (nom.)
1
Power losses (nom.)
4.35-4.93 W
Inrush current peak (max.)
31 A
-
- Wiring
-
-
Connector type input terminals
Insert
Cable capacity output wires mutual (nom.)
100 pF
Connector type output terminals
Insert
Cable length hot-wiring
0.75 m
Wire strip length
7.5-8.5 mm
Dual fixture master slave
Not applicable  [ Master Slave oper. not applicable]
Input terminal cross section
0.50-1.50 mm²
Output terminal cross section
0.50-1.50 mm²
Cable capacity output wires to earth (nom.)
100 pF
- General Information
-
Remarks UK importer address: Signify Commercial UK Limited, 3, Guildford Business Park, GU2 8XGApplication code EIIType version mk4Lamp type PL-T C L TL5CNumber of lamps 2 piece unitNumber of products on MCB (16 A type B) (nom.) 12Automatic restart Yes- Operating and Electrical
Input Voltage 220 to 240 VInput frequency 50 to 60 HzOperating frequency (max.) – kHzOperating frequency (min.) 42 kHzOperating frequency (nom.) 45 kHzIgnition method Warm StartCrest factor (max.) 1.7Power factor 100% load (nom.) 0.95Ignition time (max.) 0.52 sMains voltage performance (AC) -8%-+6%Mains voltage safety (AC) -10%-+10%Earth leakage current (nom.) 0.5 mAInrush current width 0.35 msConstant wattage deviation -2% +2%Ballast factor (nom.) 1Power losses (nom.) 4.35-4.93 WInrush current peak (max.) 31 A- Wiring
Connector type input terminals InsertCable capacity output wires mutual (nom.) 100 pFConnector type output terminals InsertCable length hot-wiring 0.75 mWire strip length 7.5-8.5 mmDual fixture master slave Not applicable  [ Master Slave oper. not applicable]Input terminal cross section 0.50-1.50 mm²Output terminal cross section 0.50-1.50 mm²Cable capacity output wires to earth (nom.) 100 pF